c
2018 Sun Hydraulics Corporation 1 of 2
MODEL
RSHC8
Pilot operated, balanced piston sequence main stage with integral
T-8A control cavity
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a normally closed modulating element that incorporates an integral pilot control
cavity. It is externally drained, and is a balanced piston design. The pilot control cavity will
accept any T-8A pressure control cartridge. When the pressure at the inlet (port 1) reaches the
pilot control cartridge's setting, the modulating element starts to open to port 2, throttling flow to
regulate the pressure. The pilot cartridge's setting determines the difference in pressure
between the inlet (port 1) and the drain (port 3). These valves are insensitive to back pressure
at port 2 , up to the valve setting. They may be used to regulate pressure in place of 2-port
relief valves if there is pressure in the return line.
TECHNICAL DATA
Cavity T-17A
Series 3
Capacity 240 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,25 - 0,33 L/min.
Response Time - Typical 10 ms
Pilot Control Cavity T-8A
Main stage leakage at 110 SUS (24 cSt) 65 cc/min.@70 bar
Valve Hex Size 31,8 mm
Valve Installation Torque 203 - 217 Nm
Seal kit - Cartridge Buna: 990017007
Seal kit - Cartridge Polyurethane: 990017002
Seal kit - Cartridge Viton: 990017006
Model Weight 0.49 kg.
snhy.com/
RSHC8
c
2018 Sun Hydraulics Corporation 2 of 2
(W)
MINIMUM CONTROL
PRESSURE
W 100 psi (7 bar)
D 25 psi (1,7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
TECHNICAL FEATURES
All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
The main stage orifice is protected by a 150 micron stainless steel screen.
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve
should then be installed into the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity.
These pilot control cartridges are sold separately and include solenoid operation, air pilot operation, and hydraulic pilot operation. See
Pilot Control Cartridges.
Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool
leakage.
Not suitable for use in load holding applications due to spool leakage.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
PERFORMANCE CURVES
RELATED MODELS
RSHC Pilot operated, balanced piston sequence valve
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered
separately and assembled at point of use.
NOTES
Model Code Example: RSHC8WNCONFIGURATION OPTIONS